Testing of power system protection

Current source PWPN-1

DESCRIPTION

Device PWPN-1 generates sinusoidal current or voltage with power frequency and controlled amplitude. It is equipped with ammeter/voltmeter.
User can choose generated and measured variable (current or voltage) by two-position switch, selected variable is indicated by LED (A or V).

PURPOSE

Current source type PWPN-1 is designated for checking current transformer load, measuring sensitivity of current protection devices etc.

TECHNICAL DATA

Current regulation range:
- at range 5 A and load up to 80 mΩ
- at range 20 A and load up to 30 mΩ

0 ÷ 5 A
0 ÷ 20 A
Voltage regulation range
with load from 15 kΩ

0 ÷ 230 V AC
Allowable uncertainty ±(1 % of reading + 1 digit)
Operation temperature
-5 ºC ÷ 50 ºC
Enclosure protection IP 67
Power supply
230 V, 50 Hz
Dimensions 270 x 246 x 174 mm
Weight about 6 kg

 